Bosch AMAX panel 2000 Installation Manual page 70

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

70
en | System Informations 2
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till the system disarmed.
3 – System Alarm
This output operates when an alarm occurs.
The output is reset:
1.
2.
When a new alarm occurred, the alarm will reset the alarm time.
If this duration is programmed as 000, the output will continue till the zone restore or system
disarmed.
4 – Entry/Exit Delay Warning
Entry Delay Warning
This output operates during Entry Time.
The output is reset:
1.
2.
3.
Exit Delay Warning
This output operates during Exit Time when the control panel is armed.
The output is reset:
1.
2.
3.
If this duration is programmed as 000, the output will continue till the delay warning duration
is up.
5 – Telephone Line Fail
This output operates when a telephone line fault occurs.
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till the telephone line is
restored.
6 – AC MAINS Fail
This output operates when a AC MAINS fault occurs.
The output is reset:
1.
2.
If this duration is programmed as 000, the output will continue till the AC MAINS power is
restored.
7 – Low Battery
This output operates when a Low Battery fault occurs.
The Dynamic Battery Test is performed every 4 hours after the system is powered up and
every time the system is armed.
The output is reset:
F.01U.241.127 | V4 | 2011.12
When the system is disarmed
When the output programmed duration is up.
When the system is disarmed and alarm is reset.
When the output programmed duration is up.
When the system disarmed
When Entry Time expires
When the output programmed duration is up.
When the system is disarmed
When Exit Time expires
When the output programmed duration is up.
When the Telephone line is restored and fault is reset.
When the output programmed duration is up.
When the AC power supply is restored