Zone Programming; Zone Types - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

AMAX panel 2000 / AMAX panel 2000 EN
1650
2970
Using one 2.2K resistor as EOL of the tamper zone, which works together with the zone EOL
2.2K. Refer to the drawing:
Figure 8.3 Dual EOL
On -board Tamper Input
A separate input is provided for enclosure tamper (This is in addition to the 8 on-board total
inputs). The response time of the tamper input is a fixed zone response time.The tamper loop
will cause a siren alarm when the loop is open, and will be reported when the loop is open
(based the "system status report option").When powered up, the system will wait for 60
seconds to setup the normal work.
Tamper Switch connector Input:
Close: NormalOpen: AlarmTamper Alarm process is the same as 24-Hour Alarm process
(Onboard Tamper is processed as zone number 17).
8.1.2

Zone programming

The programming information for each zone is stored in eight locations to determine how the
zone operates, the zone options, and the reporting information for the zone.
Zone Operating Information
These three locations store the Zone Type ( for example, Enter/Exit of Delay, Instant or 24-
Hour Zone)
Zone Options These two locations allow you to select from a number of options. Refer to
Section 8.1.4 Zone Bypass, page 62 for more information.
Zone Reporting Information
This information includes the locations for the Zone Report Code and the Zone Dialer Options.
The Zone Report Code determines whether the control panel sends Alarm Reports for the
zone. The Zone Dialer Options location enables you to specify how a zone reports to a base
station receiver.
8.1.3

Zone Types

(Refer to Section 10.4 Zone Programming, page 82).
0 and 14-15 – Zone Not Used
If a zone is not used, program the zone type location to 0 or 14-15. An EOL resistor is not
required if this zone type is not used. This zone type never activates the sirens or the dialer.
1- Instant
The instant zone will perform as below:
1.
Bosch Sicherheitssysteme GmbH
2200
4400
1
COM
Z3
Disarm:
Zone normal - no Alarm / no report
Zone triggered - no Alarm / no report
Installation Manual
2750
4950
2
System Informations 2 | en
normal
trigerred
F.01U.241.127 | V4 | 2011.12
57