Arming/Disarming The System; Isolating Zones; Standard Isolating; Code To Isolate - Bosch CC488 Quick Reference Manual

Solution ultima 880
Hide thumbs Also See for CC488:
Table of Contents

Advertisement

CC488 | Quick Reference Guide | 1.0 Overview
1.6

Arming/Disarming the System

Table 5:

Arming/Disarming the System
AWAY Mode
Arming
Press and hold the [#] key until two
(On)
beeps are heard.
Or
Enter your code followed by the [#]
key (for example, [2 5 8 0 #]).
Or
To arm all areas, enter your code
followed by [0] and then the [#] key
(for example, [2 5 8 0 0 #]).
Use a code to arm all areas
simultaneously that the code is
assigned to in AWAY Mode without
needing to arm each area individually.
Disarming
Enter your code followed by the [#]
(Off)
key (for example, [2 5 8 0 #]).
Or
To disarm all areas, enter your code
followed by [0] and then the [#] key
(for example, [2 5 8 0 0 #]).
Use a code to disarm all areas
simultaneously that the code is
assigned without needing to disarm
each area individually.
1.7

Isolating Zones

1.7.1

Standard Isolating

1. Press the [*] key twice.
2. Enter the zone number that you want isolated,
followed by the [*] key.
Repeat step 2 if more than one zone is
required to be isolated.
3. Press the [#] key to exit when finished.
1.7.2

Code to Isolate

1. Press the [*] key once.
2. Enter your user code.
3. Enter the zone number that you want isolated,
followed by the [*] key.
Repeat Step 2 if more than one zone is
required to be isolated.
4. Press the [#] key to exit when finished.
1.8
Add/Delete RF Devices (Wireless
Zones)
1.8.1

Add RF Device

1. Enter the four character Installer Code,
followed by [0] and the [#] key (for example,
[1 2 3 4 0 #]).
2. Enter the Device Number (1 to 16) you want
to add, followed by the [#] key.
3. Enter the 9-digit RF device ID number,
followed by the [#] key.
Bosch Security Systems | 6/04 | 4998152446B
STAY Mode 1
Press and hold the [*] key until two
beeps are heard.
Or
Enter your code followed by the [*]
key (for example, [2 5 8 0 *]).
Press and hold the [*] key until two
beeps are heard (only if no alarm).
Or
Enter your code followed by the [#]
key (for example, [2 5 8 0 #]).
1.8.2

Delete RF Device

1. Enter the Installer Code followed by [0] and
the [#] key (for example, [1 2 3 4 0 #]).
2. Enter the Device Number (1 to 16) you want
to delete, followed by the [#] key.
3. Press the [*] key to delete the RF device.
1.9

Set First Test Report

1. Enter the four character Installer Code,
followed by [1] and the [#] key (for example,
[1 2 3 4 1 #]).
2. Enter the Number Of Days (0 to 15) to wait
until the first test report, followed by the [#]
key.
1.10

Event Memory Recall

Enter the four character Installer Code or Master
Code, followed by [8] and the [#] key (for
example, [1 2 3 4 8 #]).
The last 40 events (non partitioned) or last ten
events (partitioned) are displayed in reverse order
(for example, most recent to least recent).
1.11

Walk Test Mode

1. Enter the four character Installer Code or
Master Code, followed by [7] and the [#] key
(for example, [1 2 3 4 7 #]).
2. Test each zone as required.
3. Press the [#] key to exit.
STAY Mode 2
Press and hold the [0] key until two
beeps are heard.
Press the [0] key until two beeps are
heard (only if no alarm).
Or
Enter your code followed by the [#]
key (for example, [2 5 8 0 #]).
EN | 8