Download Print this page

Hoshizaki KM-340MAH Manual page 4

Cleaning & sanitizing
Hide thumbs Also See for KM-340MAH:

Advertisement

Ice Machine
The ice maker must be cleaned & sanitized at least once a year.
Cleaning Prep:
1
R
Remove the Front Panel, move the control switch to OFF.
After 3 min., move the switch to ICE, then replace the panel.
2
A
After 3 min., remove the Front Panel, move the switch to OFF.
Remove all ice from the ice storage bin and/or dispenser
3
R
WARNING! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Left side of
Ice Maker
View
through side
panel
4
R
Remove the Front Insulation Panel, slide the Cube Guide to right. Remove the
Rubber Cap & Sleeve covering the Overflow Pipe. Unscrew the Overflow Pipe.
Once the water tank has drained, replace all the items.
R
Refill water tank by moving the control switch to ICE,
5
replace the Front Panel. After 3.5 minutes, remove
Front Panel, move switch to OFF.
6
Remove the Front Insulation Panels. Pour 30 fl.oz
R
(887 ml) of Hoshizaki Scale Away into the water tank.
Replace the Front Insulation Panels. Turn the
cleaning valve left until completely vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait 1 minute
before next step.
7
M
Move the control switch to WASH, replace Front Panel.
NOTICE! DO NOT leave the control switch on WASH
for extended periods when water tank is empty. It will
damage water pump seals.
After 30 minutes, remove Front Panel, then move the
A
8
control switch to OFF.
#51003 | 7.22.2016
Page 4
Cleaning & Sanitizing
continued on the back...
Tech Support: 1.800.233.1940
3
min
.
3
min.
Front of
Ice Maker
with
Front
Panel
removed
3.5
min.
OPEN
30
min.
KM-1100MAH, MWH, MRH
KM-1340MAH, MWH, MRH
KM-1601MRH/3
WARNING!
DO NOT leave icemaker unattended when
panels are off
AMMONIA
Cleaners
Sanitizing:
Fill the water tank
CLOSE
the cleaning valve
Move control switch to ICE,
replace the front panel
After 3.5 minutes, remove the
front panel
Move control switch to OFF
Remove the front insulation
panel
Pour 1.7 fl. oz (50 ml) of
chlorine bleach* into the
water tank
Replace the top, left, and
insulation panels
OPEN
the cleaning valve
* Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
Wait 1 minute to avoid
excessive foaming
Move control switch to WASH,
replace the front panel
After 45 minutes, remove
the front panel
Move control switch to OFF
Remove the front insulation
panel
Slide the cube guide to right
Remove rubber cap & sleeve
covering the overflow pipe
Unscrew overflow pipe, drain
water tank
Replace the rubber cap, sleeve,
cube guide & insulation panel
14
n
15
16
17
n
18
Page 1