Download Print this page

Hoshizaki KM-340MAH Manual page 19

Cleaning & sanitizing
Hide thumbs Also See for KM-340MAH:

Advertisement

Need Service or Repair? Locate your closest Hoshizaki Certified Service Tech: hoshizakiamerica.com/locate-service-rep
M
Move the control switch to WASH, replace Front
8
P
Panel.
NOTICE! DO NOT leave the control switch on WASH
for extended periods when water tank is empty. It will
damage water pump seals.
A
After 30 minutes, remove Front Panel, then move the
9
c
control switch to OFF.
R
Remove the Top, Left, and Insulation Panels. Remove the Distributor Hose.
10
R
Remove the Thumbscrew securing Cube Guide B, then remove both Cube Guides
B & A.
Remove the Overflow Cap, Overflow Pipe, and Drain Plug. Clean all items (See
R
11
Step 12). Once water tank has drained, replace and reconnect all the items.
S
I
In bad water conditions, a more thorough cleaning
12
may be required. Turn off power supply, clean all items
in a solution of 5 oz. of Scale Away per gallon of
warm water. Rinse and replace the cube guides, float
switch, water supply tubes, spray tubes and spray
guides. Turn on power supply. Otherwise, continue to
step
.
Cleaning Rinse:
13
Turn the cleaning valve to the right until completely
T
horizontal (closed). Move the control switch to ICE,
2
replace Front Panel. After 3 minutes, remove the
Front Panel, move switch to OFF.
NOTICE! ICE MACHINE WILL NOT WORK,
unless valve is completely closed.
T
Turn the cleaning valve to the left until completely
14
vertical (open). Move the control switch to WASH,
2
replace the Front Panel. After 5 minutes, remove
the Front Panel, switch to OFF.
Remove the Top, Left, and Insulation Panels.
R
15
Remove the Distributor Hose. Remove the
R
2
thumbscrew securing Cube Guide B, then
remove both Cube Guides B & A.
R
Remove the Overflow Cap, Overflow Pipe, and Drain Plug. Once water tank has
16
drained, replace and reconnect all the items. Continue to Sanitation – Step
front...
OPEN cleaning valve:
To allow cleaning solution flow to
the inside the evaporator
Turn left to open (vertical)
DOWNLOAD COMPLETE
INSTRUCTION MANUAL:
hoshizakiamerica.com/support
Type in the model number of your
ice machine (including dashes) to
download manuals
#51000 | 7.21.2016
ICE
WASH
Scoop
Dish soap, rinse well
Water Filters
Check psi, change if req'd
Exterior
Dish soap & damp cloth
Bin Door/Top Kit
Warm water & clean cloth
Ice Maker/Bin
Follow these instructions
Water Supply Inlet
Clean inlet screen
Condenser
Inspect. Clean with brush
Water Hoses
Inspect. Replace if req'd
Tech Support: 1.800.233.1940
30
min.
CLOSE
CONTROL PANEL
OFF
> 3 minutes >
OPEN
CONTROL PANEL
OFF
> 5 minutes >
on
CLOSE cleaning valve:
Must be closed for normal ice
making operation
Turn right to close (horizontal)
WARNING!
DO NOT use
ammonia type
cleaners. Can cause
damage to icemaker
WEAR liquid-proof
gloves and goggles to
protect skin & eyes
from cleaning &
sanitizing chemicals
sanitizing continued...
RINSE 1:
(Steps 23-26)
CLOSE
cleaning valve
Move control switch to ICE,
replace the front panel
After 3 minutes, remove the
front panel
Move control switch to OFF
OPEN
cleaning valve
Move control switch to WASH,
replace the front panel
After 5 minutes, remove the
front panel
Move control switch to OFF
Remove the top, left, and
insulation panels
Remove distribution hose
Remove thumbscrew from cube
guide B
Remove cube guide B & A
Remove the overflow cap,
overflow pipe, and drain plug
After the water tank has
drained, replace and reconnect
all the
items.
RINSE 2 & 3:
(Steps 27-34)
Repeat 2x (Steps 23–26) for
complete ice/food safety
Clean the dispenser /
storage bin liner with a
neutral cleaner (dish soap)
Rinse thoroughly
CLOSE
the cleaning valve
Move control switch to ICE
Replace all panels
NOTICE!
IF ICE MAKER IS ON DISPENSER,
remember to turn on the dispenser
after cleaning
AMMONIA
Cleaners
23
24
25
26
27
35
36
37
Page 19

Advertisement

loading