Cleaning & sanitizing
Hide thumbs Also See for KM-340MAH:

Advertisement

Ice Machine
The ice maker must be cleaned & sanitized at least once a year.
Cleaning Prep:
Remove the Front Panel, move the control switch to OFF.
R
1
A
After 3 min., move the switch to ICE, then replace the panel.
A
After 3 min., remove the Front Panel, move the switch to OFF.
2
Remove all ice from the ice storage bin and/or dispenser
R
3
WARNING! IF ON DISPENSER, turn off the dispenser power
supply after dispensing all the leftover ice.
Cleaning:
Front
View of
Ice Maker
4
Remove the Front Insulation Panel. Remove the Drain
R
Plug. Once the water tank has drained, replace the
Drain Plug and Insulation Panel.
NOTICE! DO NOT cross thread the drain plug.
R
Refill water tank by moving the control switch to ICE,
5
replace the Front Panel. After 3 minutes, remove Front
Panel, move switch to the OFF position.
R
Remove the Front Insulation Panels. Pour 43 fl.oz
6
(1
(1,272 ml) of Hoshizaki Scale Away into the water
tank. Replace the front insulation panel. Turn the
cleaning valve left until completely vertical (open).
NOTICE! AVOID EXCESSIVE FOAMING, wait
1 minute before next step.
M
Move the control switch to WASH, replace Front
7
P
Panel.
NOTICE! DO NOT leave the control switch on WASH
for extended periods when water tank is empty. It will
damage water pump seals.
#51005 | 7.22.2016
Page 12
Cleaning & Sanitizing
continued on the back...
Tech Support: 1.800.233.1940
3
min
.
3
min.
3
min.
OPEN
30
min.
KMH-2000SWH/3
KMH-2000SRH/3
WARNING!
DO NOT leave icemaker
unattended when panels are off
AMMONIA
Cleaners
Sanitizing:
Fill the water tank
CLOSE
the cleaning valve
Move control switch to ICE,
replace the front panel
After 3 minutes, remove the
front panel
Move control switch to OFF
Remove the front insulation
panel
Pour 5 fl. oz (148 ml) of
chlorine bleach* into the
water tank
Replace the front insulation
panel
OPEN
the cleaning valve
* Use bleach without additives.
Additives cause excessive foaming, and
reduces effectiveness of the cleaning.
Wait 1 minute to avoid
excessive foaming
Move control switch to WASH,
replace the front panel
After 45 minutes, remove
the front panel
Move control switch to OFF
Remove the front
insulation panel
Remove drain plug
After the water tank has
drained, replace drain plug and
insulation panel