Hoshizaki KM-340MAH Manual page 30

Cleaning & sanitizing
Hide thumbs Also See for KM-340MAH:

Advertisement

Ice Machine
The icemaker and dispenser must be cleaned & sanitized at least twice a year.
Cleaning Prep:
Close the icemaker water supply line shut-off valve.
Remove the Front Panel, move the
OFF. Move the
control switch
the
power switch
to ON. Replace the Front Panel.
Allow the water system to drain completely. Remove the Front
Panel, move the
power switch
Unplug the icemaker from the electrical outlet.
Remove all ice from the ice storage bin and/or dispenser
ATTENTION! IF ON DISPENSER, turn off the dispenser power supply after dispensing
all the leftover ice.
Cleaning:
R
Remove the Spout-to-Chute Strap
(
(includes Drip Guide on FS-1500),
then remove the Spout.
D
Dilute Hoshizaki Scale Away with
warm water (see Table).
Cleaning Solution
Scale Away
9.6 fl. oz (0.29 l)
Warm Water
1.6 gal. (6.0 l)
Pour the cleaning solution over the
Extruding
Head
Evaporator
Assembly
Reservoir are full and the solution
starts to overflow into the drain pan.
#51056 | 02.21.2018
Page 30
Cleaning & Sanitizing
power switch
to
is DRAIN, then move
to OFF. Remove the Top Panel.
until
the
and
the
Replace
the Spout,
Spout-to-Chute Strap, and Drip Guide (if applicable) in
their correct positions.
Allow the icemaker to soak for 10 minutes before operation.
continued on the back...
Tech Support: 1.800.233.1940
To Icemaker
Or Water Filter
SHUT OFF
.
Unplug
ATTENTION!
DO NOT leave icemaker
unattended when panels are off
AMMONIA
Cleaners
Sanitizing:
Dilute 5.25% chlorine bleach
with warm water
(see Table below)
Sanitizing Solution
Bleach
2.5 fl. oz (0.74 ml)
Warm Water
5 gal. (19 l)
Use bleach without additives.
Remove the top panel
Remove the spout-to-chute strap
(includes drip guide on FS-1500)
Remove
the
spout,
O-rings,
packing and chute bracket
(FS-1022
or drip guide
and smaller)
(FS-1500)
between spout and chute
Pour the sanitizing solution over
the extruding head until the
evaporator
assembly
and
reservoir are full, and it starts to
overflow into the drain pan
Remove the proximity switch
from the chute assembly, then
remove the chute assembly
Remove the packing at the bottom
of the ice chute. Remove the 3 ties,
the chute insulation, and 2 baffles
Remove the plate and the packing
from the top of the ice chute.
Remove the backup bin control
sliding it towards the chute opening &
lifting it off)
Disassemble the backup bin
control assembly by removing
the 2 snap pins, shaft, and
actuator
Soak the spout, O-rings,
packings, chute bracket
(FS-1022
, drip guide
and smaller)
(FS-1500)
chute, baffles, plate, and backup
bin control assembly in the
sanitizing solution for 10 minutes
then wipe them down
)