Special Feature: Replacing Hard Disk In The Raid System When Switched Off; Integrating A New Hard Disk Drive In The Raid System - Siemens SIMATIC IPC1047 Operating Instructions Manual

Hide thumbs Also See for SIMATIC IPC1047:
Table of Contents

Advertisement

7.3.5

Special feature: Replacing hard disk in the RAID system when switched off

The RAID system does not automatically boot up when restarted if a defective hard disk was
replaced while the RAID system is switched off. Therefore, place the RAID system in the first
place of the bootable sources in the BIOS setup menu "Boot". Otherwise, the system will
boot from the hard disk you have just installed and the message "Operating system not
found" will be displayed.
7.3.6

Integrating a new hard disk drive in the RAID system

The RAID system is configured in the delivery state so that a new hard disk must be
integrated manually in case of an error. To integrate the hard disk automatically, activate
"Automatic rebuild" in the "Preferences" menu of the RAID software.
Automatic integration of a hard disk
NOTICE
Data loss
The hard disk to be integrated is not checked for partition information or existing data
during automatic integration.
All partitions and data on the hard disk are deleted without warning. Insert only a brand-new
hard disk.
Requirement:
● "Automatic rebuild" is selected in the "Preferences" menu of the RAID software.
● The hard disk to be integrated is brand new or is set up as a spare drive. Notes on
creating spare drives are available in the controller documentation.
Sequence
The following figure is an example for the automatic rebuilding process.
SIMATIC IPC1047
Operating Instructions, 09/2018, A5E45118479-AA
Device maintenance and repair
7.3 Manage onboard RAID system
79

Advertisement

Table of Contents
loading

Table of Contents