01
Readout on -V.A.G 1552 -
01285
Side airbag front
passenger's side
deactivated
01286
Belt tensioner
driver's side deac-
tivated
01287
Belt tensioner
front passenger's
side deactivated
01299
No communication
Data bus diagnos-
tic interface
-J533-
No setting or in-
correct setting
01312
defective
Data BUS drive
01317
No communication
Control unit in
dash panel insert
-J258-
01578
Open circuit
Warning light for
airbag off on the
front passenger
side -K145-
Short circuit to
positive
4)
65535
136
no fault detected
4)
65535
000
Control unit defec-
tive
1)
Only applies for vehicles with electric belt tensioners.
2)
Erase fault memory (control unit may be used 3x at the most).
3)
The fault memory cannot be erased anymore (warning lamp -K75- flashes constantly).
4)
Index which shows the type of fault.
Reading measured value block
The measured value block is subdivided into 10 display
groups. Each display group is subdivided into max. 4 dis-
play fields.
01-6
6
page
Possible cause of fault
♦
Side airbag front passenger's
side deactivated
♦
Belt tensioner driver's side deac-
tivated
♦
Belt tensioner front passenger's
side deactivated
♦
Fault in CAN databus cables
♦
Electrical system control unit -
J519- incorrect or defective
♦
Cables or plug connections de-
fective
♦
CAN databus using control units
defective
♦
Cables or plug connections de-
fective
♦
Cables or plug connections de-
fective
If after repair „No fault detected" is displayed, the self-diagnosis is com-
pleted.
♦
Cables or plug connections de-
fective
♦
Control unit defective
Self-diagnosis for airbag system II
FABIA 2000
Rectifying fault
–
Blocking and activating airbag
units ⇒ Chapter 01-7
–
Blocking and activating airbag
units ⇒ Chapter 01-7
–
Blocking and activating airbag
units ⇒ Chapter 01-7
–
Test CAN databus lines
⇒ Electrical System;
Rep. Gr. 90
–
Read out Gateway fault memory
⇒ Electrical System;
Rep. Gr. 90
–
Check cables, plug connections
and fuses in accordance with the
current flow diagram ⇒ Current
Flow Diagrams, Electrical Fault
Finding and Fitting Locations
–
Check cables, plug connections
and fuses in accordance with the
current flow diagram ⇒ Current
Flow Diagrams, Electrical Fault
Finding and Fitting Locations
–
Check cables, plug connections
and fuses in accordance with the
current flow diagram ⇒ Current
Flow Diagrams, Electrical Fault
Finding and Fitting Locations
–
Check wiring and plug connec-
tions ⇒ Current Flow Diagrams,
Electrical Fault Finding and Fit-
ting Locations
–
Replace control unit
S00.5319.15.20
Body Work
Edition 01.05