Reading Measured Value Block - Skoda FABIA 2000 Workshop Manual

Hide thumbs Also See for FABIA 2000:
Table of Contents

Advertisement

FABIA 2000
Electrical System
90-4
Self-diagnosis of the dash
panel insert III

Reading measured value block

Readout on display:
Enter function
„Read measured value block"
0 8
and confirm the entry with key
Readout on display:
Enter display group number ⇒ 90-4 page 1.
List of display groups
Note
The display always shows the actual values of the
senders and sensors. These may differ in view of the
fact that the values which appear in the dash panel in-
sert are shown filtered!
If the actual coolant temperature is between approx.
80 C to 100 C, it is always 90 C which appears in the
display of the dash panel insert!
Measured value block 001
Reading measured value block 1
50 km/h
2400 rpm
Vehicle speed
0 through 300 km/h
Edition 05.04
S00.5304.11.20
.
Q
Oil p2< min.
0: 0 h
Sender for oil pressure
Oil p2< min.
Oil p2 o.k.
Engine speed
0 to 9990 rpm
Self-diagnosis of the dash panel insert III
Vehicle system test
Select function XX
Read measured value block
Enter display group number XXX
Readout on display
Time