Self-Diagnosis For Convenience System With Can Databus Cable; Overview Of The Selectable Functions Of The Self Diagnosis For Convenience System With Can Databus Cable; Overview Of The Control Units For Convenience System With Can Databus Cable - Skoda FABIA 2000 Workshop Manual

Hide thumbs Also See for FABIA 2000:
Table of Contents

Advertisement

FABIA 2000
Body Work
01-2
Self-diagnosis for con-
venience system with
CAN databus cable
Overview of the selectable functions of
the self diagnosis for convenience sys-
tem with CAN databus cable
Operation
01
Interrogating control
unit version
02
Interrogating fault
memory
03
Actuator diagnosis
05
Erasing fault memory
06
Ending output
07
Coding control unit
08
Reading measured val-
ue block
10
Adjustment

Overview of the control units for convenience system with CAN databus cable

Control unit part No.
Central control
Door control unit
unit for conven-
ience system
6Q0959433A 01
6Q0959433H 35
6Q0959433C 02
6Q0959433E 3A
6Q0959433C OK
6Q0959433C 03
6Q0959433E 2P
6Q0959433A 04
6Q0959433H 2Q
6Q1959 801 04/2Q
6Q1959 802 04/2Q
6Q0959433C 06
6Q0959433E 2S
6Q1959801 06/2S
6Q1959802 06/2S
6Q0959433C 08
6Q0959433E 2U
6Q1959801 08/2U
6Q1959802 08/2U
Edition 01.05
S00.5319.15.20
Page
⇒ Chap. 01-1,
⇒ Chapter 01-1
⇒ Chapter 01-1
⇒ Chapter 01-1
⇒ Chapter 01-1
⇒ Chap. 01-1 ⇒ 01-2
page 3
⇒ 01-2 page 15
⇒ Chapter 01-4
Program
1)
number
-
0002
-
0002
-
0002
-
0002
0002
TFK 0001
0002
TFK 0001
0002
TFK 0001

Self-diagnosis for convenience system with CAN databus cable

Control unit function
Control unit without power-window lifter, without radio
control and without alarm function
LHD
Control unit without power-window lifter, with radio con-
trol without alarm function
LHD
Control unit without power-window lifter, with radio con-
trol and alarm function (with interior monitoring) without
alarm system with independent power supply
LHD
Control unit without power-window lifter, with radio con-
trol and alarm function (with interior monitoring) and
alarm system with independent power supply
LHD
Control unit with 2 power-window lifters, without radio
control and alarm function
LHD
Control unit with 2 power-window lifters, with radio con-
trol and without alarm function
LHD
Control unit with 2 power-window lifters, with radio con-
trol and alarm function (with interior monitoring) and
alarm system with independent power supply
LHD
01
01-2
1
page

Advertisement

Table of Contents
loading

Table of Contents