01
Reading measured value block with LIN
databus cable
The measured value block is subdivided into 15 display
groups. Each display group is subdivided into max. 4 dis-
play fields.
Readout on display:
Enter function 08.
Readout on display:
Confirm the entry with key
Readout on display:
Select desired display group number and confirm en-
try with
.
Q
Readout on display:
The breakdown of the display contents in the individual
display fields is available in the test table. Test table.
To switch to another display field: Press
End measured value block test:
Press
key.
C
Readout on display:
Note
After ending the function „Reading measured value
block" interrogate the fault memory ⇒ Chap. 01-1.
If the CAN databus is defective, the text „CU does not
answer" will be displayed instead of „Read measured
value block".

Test table with LIN databus cable

Display group 001
Display
Readout on dis-
field
play
1
1)
not fitted
2
1)
not fitted
3
1)
not fitted
1)
Ignore.
01-3
10
page
.
Q
or
.
Denomination
Central switch for window lifter:
switch for window lifter DS
WL thermo fuse DS
Child safety catch switch
Self-diagnosis for convenience system with LIN databus cable
Vehicle system test
Select function XX
Vehicle system test
08
Read measured value block
Reading measured value block
Enter display group number
Reading measured value block
1
2
Vehicle system test
Select function XX
Rectifying fault
Check window lifter switch for correct fit-
ting and tightness.
Check relevant plug connections for cor-
rect fitting and tightness.
Check relevant cables according to valid
current flow diagram ⇒ Current Flow Di-
agrams, Electrical Fault Finding and Fit-
ting Locations.
Perform a functional test.