Agilent Technologies N9310A User Manual page 40

Rf signal generator
Hide thumbs Also See for N9310A:
Table of Contents

Advertisement

3
Using Functions
Sweep
Trigger
IMM
IMM
34
Additional Settings for a Step Sweep
There are also other four setting items that have effects on
the sweep:
• Sweep Trigger
You can set the sweep trigger to any of the following
three choices: Immediate/Trigger Key/EXT
• Point Trigger:
You can set the point trigger to any of the following three
choices: Immediate/Trigger Key/EXT
• Sweep Repeat: Cont/Single
You can set the sweep repeat to either Cont or Single.
If set to Cont, the signal generator sweeps from the start
point to the stop point and cycles continuously.
If set to Single, the signal generator sweeps from the start
point to the stop point for only one circle.
• Sweep Direction: Up/Down
Take RF sweep for example, as you enable RF sweep by
pressing
Sweep Mode > RF, the signal generator performs as
>
Sweep
below, according to combinatorial settings of sweep trigger
and point trigger.
Point
Sweep Performance
Trigger
IMM
Pressing
Sweep
automatically. Pressing
Key
Pressing
Sweep
pressing the Trigger key initiates sweeping over the points
manually.
>Sweep mode > RF initiates sweeping immediately and
>Sweep mode >Off closes the sweep.
Sweep
>Sweep mode > RF enables the RF sweep, then
N9310A User's Guide