Upgrading To 4X Pcie 2.5-Inch Ssd Configuration; Preliminary Steps - Fujitsu PRIMERGY TX1320 M4 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX1320 M4:
Table of Contents

Advertisement

7.4.9

Upgrading to 4x PCIe 2.5-inch SSD configuration

I
A PCIe backplane can only be installed as the first backplane. Mixing of
an HDD backplane and a PCIe SSD backplane is not allowed. A PCIe
SSD backplane needs a PRAID EP5x0i, see section
EP5x0i" on page
Field Replaceable Unit
(FRU)
Tools: Phillips PH2 / (+) No. 2 screw driver
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost when deleting the
RAID array! Be sure to back up your data before deleting a RAID array.
For more information, see the "ServerView Suite RAID Management"
user guide.
I
After installing or removing an additional backplane, never forget to
change the system information using the Chassis ID Prom Tool.
7.4.9.1

Preliminary steps

I
The HDD backplane is mounted on the HDD cage. It is not necessary to
remove the HDD cage before installing or removing the HDD backplane.
"Shutting down the server" on page 49
Ê
"Disconnecting the power cord" on page 50
Ê
Ê Remove all HDD/SSD modules from the server, see section
inch HDD/SSD modules" on page
"Getting access to the component" on page 51
Ê
Ê Remove all HDD fan modules, see section
on page
165.
Ê Remove all HDD backplanes, see section
backplane" on page
TX1320 M4
Hard disk drives (HDD) and solid state drives (SSD)
183.
146.
151.
Upgrade and Maintenance Manual
"Example PRAID
Hardware: 10 minutes
"Removing the HDD fan module"
"Removing a 2.5-inch HDD/PCIe
"Removing 2.5-
161