Viessmann VITOPEND 200 Installation And Service Instructions Manual page 84

Gas fired combi boiler
Table of Contents

Advertisement

Troubleshooting
Fault codes
(cont.)
Display
Const.
Weath.‐
fault
comp.
code
dd
X
dE
X
E4
X
X
E5
X
X
E6
X
X
F0
X
X
F2
X
X
84
System char-
Cause
acteristics
Regulated op-
Room tem-
eration without
perature
room influence
sensor, heat-
ing circuit A1
lead broken
Regulated op-
Room tem-
eration without
perature
room influence
sensor, heat-
ing circuit
M2 lead bro-
ken
Fault – sup-
Burner
blocked
ply voltage
24 V
Fault – flame
Burner
blocked
amplifier
Burner control
Flue gas/
unit fault
ventilation
system
blocked
Burner
Internal fault
blocked
Burner control
Temperature
unit fault
limiter has
responded
Remedy
Check the room
temperature sen-
sor, heating cir-
cuit A1 and the
remote control
DIP switch set-
tings (see
page 110)
Check the room
temperature sen-
sor, heating cir-
cuit M2 and the
remote control
DIP switch set-
tings (see
page 110)
Replace the con-
trol unit
Replace the con-
trol unit.
Check the flue
gas/ventilation
system and air
pressure switch;
press "E"
Replace the con-
trol unit
Check the heating
system fill level,
the circulation
pump, the tem-
perature limiter
and connecting
cables/leads;
ventilate the sys-
tem; press "E"