Viessmann VITOPEND 200 Installation And Service Instructions Manual page 68

Gas fired combi boiler
Table of Contents

Advertisement

Coding
Code 2
(cont.)
Coding in the delivered condition
F2:8
Time limit for party
mode 8 h or external
heating mode change-
over via the keypad
(only for weather‐com-
pensated control units)
*
1
F5:8
Run‐on time of the inter-
nal circulation pump in
heating mode (only for
constant temperature
control units)
F6:25
In the "DHW only" oper-
ating mode, the internal
circulation pump is per-
manently ON (only for
constant temperature
control units)
F7:25
In the "Standby" operat-
ing mode, the internal
circulation pump is per-
manently ON (only for
constant temperature
control units)
Burner
F8:–5
Temperature limit for
terminating the reduced
mode ‐5 ºC, see exam-
ple on page 108.
Observe the setting of
coding address "A3".
(only for weather‐com-
pensated control units)
*1
Party mode ends automatically in heating program"rw" when the system changes
over to operation with standard room temperature.
68
Possible change
F2:0
No time limit for party
*
1
mode
F2:1
Time limit adjustable from
to
1 to 12 h
F2:12
F5:0
No run‐on time of the in-
ternal circulation pump
F5:1
Run‐on time of the inter-
to
nal circulation pump ad-
F5:20
justable from 1 to 20 min
F6:0
In the "DHW only" operat-
ing mode, the internal cir-
culation pump is
permanently OFF
F6:1
In the operating mode
to
"DHW only", the internal
F6:24
circulation pump will be
started 1 to 24 times per
day for 10 min respec-
tively.
F7:0
In "Standby mode", the
internal circulation pump
is permanently OFF
F7:1
In "Standby" mode, the
to
internal circulation pump
F7:24
in operating mode will be
started 1 to 24 times per
day for 10 min respec-
tively.
F8:+10
Temperature limit adjus-
table from +10 to ‐60 °C
to
F8:–60
F8:–61
Function disabled
*
1