Installation steps

Flue gas connection

A Tensioning screws on the flue out-
let flange
B Parallel boiler adaptor for vertical
and horizontal installation of the
flue gas system (80/80)
C Coaxial boiler adaptor for vertical
installation of the flue gas system
(60/100, 70/110 and 80/125)
D Boiler adaptor bend for horizontal
installation of the flue gas system
(60/100, 70/110 and 80/125)
10
1. Release the tensioning screws on
the flue outlet flange.
2. Insert the boiler adaptor.
Note
Fit parallel boiler adaptor C so
that its connector points towards
the left or right.
3. Tighten the tensioning screws.
Flue gas system installation
instructions