Viessmann VITOPEND 200 Installation And Service Instructions Manual page 32

Gas fired combi boiler
Table of Contents

Advertisement

Initial start-up, inspection, maintenance
Further details regarding the individual steps
5. Unscrew the combustion chamber
frame G.
6. Unscrew the combustion chamber
cover F.
7. Separate plug‐in connector B.
8. Pull the ignition cable plug from
ignition unit D and release from
the air box.
9. Pull the earth cable off the burner.
32
(cont.)
10. Remove fixing screws A and
remove burner C.
11. Clean the burner, if necessary,
with compressed air or with a
soapy solution.
Flush with clean water.
Note
Remove the ignition and monitor-
ing electrodes when cleaning with
a soapy solution or water.