Viessmann VITOPEND 200 Installation And Service Instructions Manual page 77

Gas fired combi boiler
Table of Contents

Advertisement

Scanning operating conditions and sensors
Display screen
Burner, ...h
Burner starts, ...
Time
Date
Burner OFF/ON
Int. pump OFF/ON
Int. output OFF/ON
heating circuit pump OFF/ON
Central fault message OFF/
ON
Mixer open/close
Various languages
Constant temperature control units
Press the following keys:
1. c
The following operating conditions can be scanned subject to the actual
equipment level:
Display screen
Explanation
1
15
°C/°F
Actual outside temperature
3
65
°C/°F
Actual boiler water temperature
5
50
°C/°F
Actual cylinder temperature
P
Burner hours run (after maintenance, reset to "0" using e)
263572
h
PPP
Burner starts (after maintenance, reset to "0" using e)
030529
PPPP
Fuel consumption
030417
Explanation
Actual hours run
Hours run and burner starts (reset to "0" after
maintenance, using e).
Output 20
If an internal extension is installed
If an external extension or extension kit for one
heating circuit with mixer is installed
If an external extension is installed
If an extension kit for a heating circuit with mixer
is installed
The respective languages can be selected as
permanent display language with d.
2. a/b for the required operating
condition
3. d
Terminate the scan.
Service scans
(cont.)
77