5
Commands by Subsystem
:CHANnel<n>:UNITs
Command Syntax
:CHANnel<n>:UNITs <units>
<units> ::= {VOLT | AMPere}
<n> ::= {1 | 2} for the two channel oscilloscope models
<n> ::= {1 | 2 | 3 | 4} for the four channel oscilloscope models
The :CHANnel<n>:UNITs command sets the measurement units for the
connected probe. Select VOLT for a voltage probe and select AMPere for a
current probe. Measurement results, channel sensitivity, and trigger level
will reflect the measurement units you select.
Query Syntax
:CHANnel<n>:UNITs?
The :CHANnel<n>:UNITs? query returns the current units setting for the
specified channel.
Return Format
<units><NL>
<units> ::= {VOLT | AMP}
See Also
206
(see
page
658)
"Introduction to :CHANnel<n> Commands"
":CHANnel<n>:RANGe"
":CHANnel<n>:PROBe"
":EXTernal:UNITs"
on page 227
Agilent InfiniiVision 5000 Series Oscilloscopes Programmer's Guide
on page 204
on page 199