Siemens Sinumerik 840D sl Programming Manual page 501

Job planning
Hide thumbs Also See for Sinumerik 840D sl:
Table of Contents

Advertisement

ATOL
Note
CTOL and OTOL have priority over ATOL.
General conditions
Scaling frames
Scaling frames affect programmed tolerances in the same way as axis positions; in other
words, the relative tolerance remains the same.
Example
Program code
COMPCAD G645 G1 F10000
X... Y... Z...
X... Y... Z...
X... Y... Z...
CTOL=0.02
X... Y... Z...
X... Y... Z...
X... Y... Z...
ASCALE X0.25 Y0.25 Z0.25
X... Y... Z...
X... Y... Z...
X... Y... Z...
CTOL=–1
X... Y... Z...
X... Y... Z...
X... Y... Z...
Job planning
Programming Manual, 02/2011, 6FC5398-2BP40-1BA0
8.8 Programmable contour/orientation tolerance (CTOL, OTOL,
Command for programming an axis-specific tolerance
ATOL is valid for:
All compressor functions
ORISON orientation smoothing
All rounding types except G641, G644, OSD
Name of the axis for which an axis tolerance is to be programmed
<axis>:
The value for the axis tolerance will be specified as a length or an
<value>:
angle dependent on the axis type (linear or rotary axis).
Type:
REAL
Unit:
for linear axes:
for rotary axes:
Comment
; Activate COMPCAD compressor function.
; The machine and setting data is applied here.
; A contour tolerance of 0.02 mm is applied starting
; A contour tolerance of 0.005 mm is applied
; The machine and setting data is applied again
inch/mm (dependent on the
current dimensions setting)
degrees
from here.
starting from here.
starting from here.
Path traversing behavior
501

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinumerik 840de slSinumerik 828d

Table of Contents