Checking The Serverboard Setup - Supero SUPERSERVER 6014P-T User Manual

Super micro computer 6014p-t, 6014p-tr superserver user's manual
Table of Contents

Advertisement

S
S
UPER
ERVER 6014P-T/6014P-TR User's Manual
2-5

Checking the Serverboard Setup

After you install the 6014P-T/6014P-TR in the rack, you will need to open
the top cover to make sure the serverboard is properly installed and all the
connections have been made.
1. Accessing the inside of the System (see Figure 2-5)
First, release the retention screws that secure the system to the rack. Grasp the
two handles on either side and pull the system straight out until it locks (you will
hear a "click"). Next, depress the two buttons on the top of the chassis to release
the top cover (1). Push the cover away from you (toward the rear of the chassis)
until it stops (2). You can then lift the top cover from the chassis to gain full access
to the inside of the server.
To remove the system from the rack completely, depress the locking tabs in the
chassis rails (push the right-side tab down and the left-side tab up) to continue to
pull the system out past the locked position.
2. Check the CPUs (processors)
You should have one or two processors already installed in the serverboard. Each
processor needs its own heatsink. See Chapter 5 for instructions on processor and
heatsink installation.
3. Check the system memory
Your server system may have come with system memory already installed. Make
sure all DIMMs are fully seated in their slots. For details on adding system memory,
refer to Chapter 5.
4. Installing add-on cards
If desired, you can install add-on cards to the system. See Chapter 5 for details
on installing PCI add-on cards.
5. Check all cable connections and airfl ow
Make sure all power and data cables are properly connected and not blocking the
chassis airfl ow. See Chapter 5 for details on cable connections.
2-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Superserver 6014p-tr

Table of Contents