Code 2 - Viessmann VITODENS 343-F WS4A Installation And Service Instructions Manual

Compact energy tower with a gas fired condensing boiler as compact model; natural gas and lpg version
Table of Contents

Advertisement

Coding
Code 1
(cont.)
Coding
Coding in the delivered condition
Summer econ. M2
A5:5
With heating circuit
pump logic function
Min. flow temp. M2
C5:20
Electronic minimum
flow temperature limit
20 °C
Max. flow. temp. M2
C6:75
Electronic maximum
flow temperature limit
set to 75 °C
Slope M2
d3:14
Heating curve slope =
1.4
Level M2
d4:0
Heating curve level = 0

Code 2

Complete overview
Calling up code 2
Note
On weather-compensated control
units, codes are displayed as plain
text.
Codes that are irrelevant due to the
system equipment level or the set-
ting of other codes will not be dis-
played.
68
Possible change
A5:0
Without heating circuit
pump logic function
C5:1
Minimum limit adjustable
to
from 1 to 75 °C
C5:75
C6:10
Maximum limit adjustable
to
from 10 to 75 °C
C6:75
d3:2
Heating curve slope ad-
to
justable from 0.2 to 3.5
d3:35
(see page 54)
d4: 13
Heating curve level ad-
to
justable from 13 to 40
d4:40
(see page 54)
Press the following keys:
1. L + G simultaneously for
approx. 2 s.
2. d
to confirm.
3. a/b
for the required coding
address; the address
flashes.