Checking the fuse in the Vitosolic 100
1. Switch OFF the power.
2. Fit the cover of the Vitosolic 100.
Extension kit for heating circuit with mixer
Checking the rotational direction of
the mixer motor
1.
Switch ON/OFF switch A at the
extension kit first OFF and then ON
again. The device will carry out the
following self-test:
Mixer "Close" (150 s)
Pump "ON" (10 s)
Mixer "Open" (10 s)
Mixer "Close" (10 s)
Then standard control mode
resumes.
110
3. Check fuse A.
2. Note the rotational direction of the
mixer motor during its self-test.
Then set the mixer manually to
"Open" again.
Note
The flow temperature sensor must
now capture a higher temperature.
If the temperature falls, either the
motor is turning in the wrong direc-
tion or the mixer set is incorrectly
fitted.
Mixer installation instruc-
tions