Preparing for installation

Product information

Vitodens 343-F, WS4A
Set up for operation with natural gas.
May be converted to LPG.
The Vitodens 343-F should generally only be delivered to those countries speci-
fied on the type plate. For deliveries to alternative countries, an approved con-
tractor, on his own initiative, must arrange individual approval in accordance
with the law of the land.

Handling

To protect the equipment, transport
the system inside its crate, where
possible. Whilst handling the device,
leave the pallet beneath the unit,
where possible.

Positioning

Installation room requirements
Required room height: min. 2400 mm.
Total weight incl. DHW fill: 495 kg.
6
!
Please note
To avoid equipment damage
whilst handling the device with-
out its crate or pallet, never
place the device
on its front or side panels or
apply loads to these areas.
Height of unit when tilted
With pallet 2395 mm
Without pallet 2085 mm
!
Please note
To prevent building damage,
observe the permissible
floor loading.