Coupling With The Fittings; Installation Of Rotary Joint And Coolant Joint (Hollow Shaft Specifications) - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
1 Installation

1.2.5 Coupling with the Fittings

[1]
We recommend you to adjust the dynamic balance (field balance) before fastening a belt.
[2]
The position deviation in the axial direction between the motor pulley and spindle side pulley should be as small as
possible and perform parallel correcting carefully.
[3]
If the selection or tension of belt is incorrect, an excessive force is applied to the shaft end and bearings, which may
result in shorter life or damages.
[4]
When the load by the belt exceeds the tolerable radial load of the motor, reselect the motor or belt/pulley.
[5]
Use an appropriate tension gauge to measure a belt tension.

1.2.6 Installation of Rotary Joint and Coolant Joint (Hollow Shaft Specifications)

Attach the fittings such as pulley, gear, coupling, and coolant joint to the motor output shaft when connecting a spindle
motor to a spindle. The incorrect selection of fittings or inadequate installation accuracy can generate abnormal vibration
or noise at the coupling. It can also shorten the motor or bearing life, and can damage them (fretting or flaking). Contact
the manufacturer with any questions regarding the fittings mentioned above.
Coupling
< Reference > Bearing damage
Fretting:
Fretting occurs when contact surfaces produce abrasive red-rust powders, which wear contact surfaces and make small
dimples on them. If fretting occurs on the raceway surfaces, dimples are made in the rolling element pitch. Adding
vibration load on the contact parts generates a small amplitude oscillation, which forces out lubrication from those parts
until there is no lubrication, resulting in significant wear.
Flaking:
Flaking occurs when small pieces of bearing raceway surfaces peel off due to rotation fatigue. It may occur in an early
stage due to an excessive load, handling fault, inadequate accuracy of shaft or housing, or a load application by incorrect
installation.
IB-1501229-F
Spindle motor
Coolant joint
16
Rotary joint