Connection Of The Speed Command Synchronization Control System - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
2 Wiring and Connection

2.4.3 Connection of the Speed Command Synchronization Control System

Connecting the position command synchronous control system, connect each system as an independent axis.
(1) Connecting SIN wave signal output linear scale (when using MDS-E/EH-V2)
For the FB signal of the linear scale, the SIN wave signal is converted to Mitsubishi serial signal with the encoder
conversion unit (MDS-EX-HR-11), and that signal is divided to each axis control inside the 2-axis drive unit.
Linear scale
( SIN wave signal output )
(2) Connecting Mitsubishi serial signal output linear scale (when using MDS-E/EH-V2)
The FB signal of the linear scale is divided to each axis control inside the 2-axis drive unit. An external option unit is
not required.
Linear scale
( Mitsubishi serial signal output )
CNV2E cable
Max. 30m
CN3L
CNV2E cable
Max. 30m
Secondary axis
Primary axis
Cable
prepared
MDS-EX-HR-11
by user
Encoder conversion unit
CNV2E cable
Max. 30m
CN3L
CNV2E cable
Max. 30m
Secondary axis
Primary axis
Cable prepared by user
Max. 30m
73
MDS-E/EH-V2
CN2L
CN2M
CNV2E-HP
cable
Max. 30m
Encoder type setting
Primary axis: SV025=A2xx
Secondary axis: SV025=D2xx
MDS-E/EH-V2
CN2L
CN2M
Encoder type setting
Primary axis: SV025=A2xx
Secondary axis: SV025=D2xx
IB-1501229-F