1 Installation

1.2 Installation of Spindle Motor

CAUTION
1. Do not hold the cables, axis or encoder when transporting the motor. Failure to observe this could lead to faults or
injuries.
2. Securely fix the motor to the machine. Insufficient fixing could lead to the motor deviating during operation. Failure to
observe this could lead to injuries.
3. When coupling to a motor shaft end, do not apply an impact by hammering, etc. Failure to observe this could lead to
motor failures such as the shaft distortion or bearing/encoder damage.
4. Never touch the motor during operations or right after the stop. Install a cover, etc., on the rotary sections.
5. Do not apply a load exceeding the tolerable load onto the servo motor shaft. The shaft could break. Failure to observe
this could lead to injuries.
6. Do not connect or disconnect any of the connectors while the power is ON.
7. When coupling the motor directly with the spindle, perform the adequate centering and parallel correcting with the axis to
be coupled. The vibration of the motor should be 4.9m/s
8. Perform a running-in before operating the machine.

1.2.1 Environmental Conditions

Environment
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Atmosphere
Altitude
Vibration
IB-1501229-F
2
(0.5G) or less after balancing the spindle unit.
Conditions
0°C to +40°C (with no freezing)
90%RH or less (with no dew condensation)
-20°C to +65°C (with no freezing)
90%RH or less (with no dew condensation)
Indoors (Where unit is not subject to direct sunlight)
No corrosive gases, flammable gases, oil mist or dust
Operation/storage: 1000m or less above sea level
Transportation: 10000m or less above sea level
2
X:29.4m/s
(3G) Y:29.4m/s
12
2
(3G)