Installation Direction And Clearance - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
1 Installation

1.4.2 Installation Direction and Clearance

Wire each unit in consideration of the maintainability and the heat dissipation, as well as secure sufficient space for
ventilation.
Installation clearance
100mm
or more
10mm
or
more
100mm
or more
CAUTION
1. The ambient temperature condition for the power supply unit or the drive units is 55°C or less.
2. Because heat can easily accumulate in the upper portion of the units, give sufficient consideration to heat dissipation
when designing the panel. If required, install a fan in the panel to agitate the heat in the upper portion of the units.
Panel structure of the unit back face
The type '(a)' that has substantial cooling effect is recommended.
(a) Back face inlet type
 
10mm
or
more
1mm or more
(b) Side face inlet type
Filter
Filter
Cooling will be more high-
efficiency by installing a partition
plate inside to separate inlet and
exhaust.
Fan inlet hole
For MDS-E-V3-80/EH-V3-40,
open this part and enter the fins
through the hole.
100mm
or more
80mm
or more
100mm
or more
A
Radiation fin size
Installation clearance A
60mm/67mm
75mm or more
75mm
80mm or more
92mm
114mm or more
Install a partition plate inside
to separate inlet and exhaust.
Fan inlet hole
For MDS-E-V3-80/EH-V3-40,
open this part and enter the fins
through the hole.
27
60mm
Exhaust
or
more
60mm
260
Inlet
mm
Filter
60mm
60mm
Exhaust
or
more
IB-1501229-F

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents