MDS-E/EH Series Instruction Manual
2 Wiring and Connection

2.7.4 Proximity Switch Orientation

(1) Electrical specifications
Use a proximity switch which satisfies the following specifications.
(2) Connecting with the drive unit
(a) When DICOM is connected to 24V
< Connection details: For proximity switch of two wire system >
< Connection details: For proximity switch of three wire system >
(b) When DICOM is connected to 24G
< Connection details: For proximity switch of two wire system >
< Connection details: For proximity switch of three wire system >
CAUTION
1. Supply the 24VDC power externally.
2. Install a proximity switch at the spot that rotates in the ratio of 1:1 to the spindle.
3. Set the spindle parameter to the pulley ratio for belt drive or to the gear ratio for gear drive.
Item
Output method
DC double wire system /three wire system
Power supply voltage
Response frequency
Load current
Residual voltage
Leakage current
MDS-E/EH-SP
CN9
20 DICOM
13
DI1
4.1k
24VDC
Case
ground
MDS-E/EH-SP
CN9
20
DICOM
13
DI1
4.1k
24VDC
Case
ground
MDS-E/EH-SP
24VDC
CN9
20
DICOM
13
DI1
4.1k
Case
ground
24G
Not usable.
Specification
24V DC
400Hz or more
14mA or more
4V or less
1mA or less
Proximity switch
Shield
Current direction
Proximity switch
Shield
Current direction
Select the polarity of DICOM
Proximity switch
Shield
Current direction
97
Detection circuit
Detection circuit
Detection circuit