Setting Dip Switch - Mitsubishi Electric MDS-E Series Instruction Manual

Table of Contents

Advertisement

MDS-E/EH Series Instruction Manual
4 Setup
< Power supply unit >
MDS-E/EH-CV setting

4.1.2 Setting DIP Switch

Setting the DIP switches is necessary prior to turning ON the power. Setting of the DIP switches at the time of turning ON
the power is validated. The DIP switches shall be as the standard setting (all the switches OFF).
CAUTION
An axis set unused is not included in the functional safety.
Power supply unit
(MDS-E/EH-CV)
Rotary switch setting
0
1 to 3
4
5 to F
The switches are OFF when facing bottom as illustrated.
S axis Setting unused axis
M axis Setting unused axis
L axis Setting unused axis
Setting items
Normal setting
Setting prohibited
External emergency stop setting
Setting prohibited
Unused axis can be set by turning the switches ON.
When there is unused axis for the drive unit,
set unused axis.
113
IB-1501229-F

Hide quick links: