Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 73

Hide thumbs Also See for iSeries Series:

Advertisement

Reference Code
Description/Action Perform all actions before exchanging Failing Items
00A0
SPCN BATs in process
No action required. This reference code is logged for information only. If
this reference code is present for more than 1 minute, exchange the failing
items.
00A1
Regulator 1 has been turned off by system
No action required. This reference code is logged for information only.
00A2
Regulator 2 has been turned off by system
No action required. This reference code is logged for information only.
00A3
Regulator 3 has been turned off by system
No action required. This reference code is logged for information only.
00A4
Regulator 4 has been turned off by system
No action required. This reference code is logged for information only.
00A5
Regulator 5 has been turned off by system
No action required. This reference code is logged for information only.
00A6
Regulator 6 has been turned off by system
No action required. This reference code is logged for information only.
00A7
The system is running on the Battery Power Unit.
No action required. This reference code is logged for information only.
00A8
The Battery Power Unit is not fully charged.
No action required. This reference code is logged for information only.
00A9
Battery Power Unit test is in process.
No action required. This reference code is logged for information only.
00AA
Download in process
No action required. This reference code is logged for information only.
00AB
Rack UEPO switch is OFF.
Informational reference code.
The UEPO switch must be returned to the On position to power on the
rack.
00AC
Detected AC loss
If system powers on normally or stays powered on after AC power failure,
no replacement of parts may be needed.
00BA
The system is running on the Battery Power Unit.
No action required. This reference code is displayed for information only.
00BC
Battery Power Unit test is in process.
No action required. This reference code is displayed for information only.
00CA
CPM power down is complete.
No action required. This reference code is displayed for information only.
00EF
Remote EPO switch is OFF
1xxx
Failing Item
TWRCARD
TWRCARD
CTLPNL
6462417
ACMODUL
69
System Reference Codes

Advertisement

loading