Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 38

Hide thumbs Also See for iSeries Series:

Advertisement

1xxx
Reference Code
Description/Action Perform all actions before exchanging Failing Items
4415
Battery Power Unit missing
4416
Internal Battery Power Unit Charger Fault
4417
Battery Charger Unit missing
4500 to 4502
UPS Enable/Disable Failure
4503
UPS CPM Failure
4504
UPS Battery Failure
4505
UPS Unit Failure
4507
UPS Enable/Disable Failure
4510
UPS Test Failure
4513
UPS Interface Failure
6018
One of the regulators has reported a fault
A regulator fault was detected.
601A
One of the CPM regulators has reported a fault
A CPM regulator fault was detected.
6118
Regulator over current fault
One of the regulators detected an over current condition. This may be
caused by the regulator or one of cards powered by the regulator.
6218
Regulator over current fault
Regulator 1 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6238
Regulator over current fault
Regulator 2 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6258
Regulator over current fault
Regulator 3 detected an over current condition. This may be caused by the
regulator or one of cards powered by the regulator.
6318
Regulator Fault
Regulator 1 has reported a fault.
631A
Regulator Fault
Regulator 1 has reported a fault.
34
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference Codes)
Failing Item
BATRY
TWRCARD
CBLALL
BATCHGR
TWRCARD
CBLALL
BATCHGR
TWRCARD
CBLALL
UPSUNIT
TWRCARD
UPSUNIT
TWRCARD
BATRY
UPSUNIT
UPSUNIT
TWRCARD
UPSUNIT
TWRCARD
UPSUNIT
TWRCARD
UPSUNIT
TWRCARD
PWRREG
BKSPCN
PWRREG
BKSPCN
FI00030
PWRREG
BKSPCN
PWRREG
BKSPCN
PWRREG
BKSPCN
PWRREG
ACMODUL
PWRREG
BKSPCN
PWRREG
ACMODUL
FI00030

Advertisement