Download Print this page

IBM iSeries Series Analyze Hardware Problems (System Reference Codes page 204

Hide thumbs Also See for iSeries Series:

Advertisement

A1xx, B1xx
Reference Code
Description/Action Perform all actions before exchanging Failing Items
8FF0
Information only, no service action required
Service processor error log entry.
If the secondary refcode is 806A, a successful
download of control panel code has occured.
If the secondary refcode is 8EEE, one of the following
conditions may have occured.
Operation was successful but current
keylock position was not in Auto or normal.
The Time-of-Day (TOD) chip had to be reset
due to an invalid power-up state. TOD
requests will not work successfully until
a write TOD is done (CHGSYSVAL QDATE).
Timed-Power-On request has been acknowledged.
Power on sequences must be set for valid months,
days, hours, minutes, and seconds, for future
times, and for times when the system will be
powered off.
8FF1
System down, condition reported
Table 2. Service Processor Failing Items Details
Failing Item
Description
AJDG301
Licensed Internal Code
AJDGP01
Service processor Licensed Internal Code
ALTINTF
System bus
AUSTIN0
RESERVED - Austin Only code - flash update
by diskette
BACKPLN
Back Plane Unit
BUS1
System bus
CECPWR
Power supply
CLCKCRD
Clock Card
CLKCARD
Clock Card
CTLPNL
Control Panel, or the interface to the Control
Panel
HSLCTLR
System processor card
IOPWR
Power Supply
IPLINTF
System bus
JTPORT
System Interconnect cable, connection or
interposer card
LSMEDIA
Tape, DASD or Optical Media
MSTORE
Main storage cards
OPUSR
Operator/User Error
PROC
System processor card
200
iSeries: iSeries 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Analyze Hardware Problems (System Reference
Codes)
Document Description
Service Functions; APAR or LICTR
Service Functions; APAR or LICTR
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
Problem Analysis; Symbolic FRU Isolation
System Operations: Operator's Guide SC41-8082
Problem Analysis; Symbolic FRU Isolation
Failing Item