Reference Code
Description/Action Perform all actions before exchanging Failing Items
9200
I/O processor addressed the tape unit; no response
Before exchanging any parts, do the following:
1. Ensure that the device is powered on.
2. Ensure that the SCSI cable between the device and the I/O Processor or
I/O Adaptor is seated correctly, and that there are not bent or damaged
pins on the SCSI cable.
3. Ensure that the terminating plug is attached to the device.
9201
Tape unit command timeout
Before exchanging any parts, do the following:
1. Ensure that the device is powered on.
2. Ensure that the SCSI cable between the device and the I/O Processor or
I/O Adaptor is seated correctly, and that there are not bent or damaged
pins on the SCSI cable.
3. Ensure that the terminating plug is attached to the device.
9202
Tape unit failed after Licensed Internal Code was loaded
Before exchanging any parts, do the following:
1. Ensure that the device is powered on.
2. Ensure that the SCSI cable between the device and the I/O Processor or
I/O Adaptor is seated correctly, and that there are not bent or damaged
pins on the SCSI cable.
3. Ensure that the terminating plug is attached to the device.
9210
Illegal or unsupported tape unit response
9300
Tape unit failure
The tape drive reported a hardware error to the IOP; the amber light on
the tape drive may be blinking.
Perform TU-PIP2.
9301
Tape device failure, redundancy lost
The tape device detected a hardware failure that does not prevent the tape
unit from completed the current operation.
Refer to the Tape unit service information to determine the failing item.
9302
Tape device failure or media error
The tape unit detected a failure that may be caused by a hardware failure
or a media error.
Refer to the tape unit service information for possible information on
diagnostic tests that can be run to isolate between hardware and media
failures.
9310
Licensed Internal Code for the tape unit is not correct
9320
Tape device Licensed Internal Code failure
7208
Failing Item
46G2227
46G3934
FI00830
FI00131
46G2599
17G1500
42F7300
46G2227
46G3934
FI00830
FI00131
46G2599
17G1500
42F7300
46G2227
46G3934
FI00830
FI00131
46G2599
17G1500
42F7300
46G2227
FI00130
FI00131
46G2227
ML2TMED
46G3934
42F7300
46G2227
ML2TMED
46G3934
42F7300
ML2TMED
46G2227
46G3934
42F7300
46G2227
FI00130
FI00130
46G2227
189