Performing A Diagnostics Session - Siemens SINUMERIK 840D sl Function Manual

Sinumerik integrate amb, amc, amm
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

7 Establishing a connection and diagnostics
7.3 Client diagnostics

7.3.2 Performing a diagnostics session

Start of the diagnostics session
Start the diagnostics session with the "Start Session" softkey to execute the
following actions:
Rename existing log files
Create new log files with maximum LOG level
Executing SINUMERIK Integrate functions that cause problems
Functions are executed that cause problems and shall be diagnosed.
Stopping the diagnostics session
Stop the diagnostics session with the "Stop Session" softkey to execute the
following actions:
Place script files in a buffer
Place log files generated during the session in a buffer
Place SETTINGS.INI in a buffer
Place file with session information in XML format in a buffer
Reset LOG level to default value
Storing the LOG data
Generated data can be stored on any storage medium as long as it can be
accessed online. Pressing the "Save Data" softkey starts an application that allows
you to save any data you have generated as a ZIP file.
You can enter a storage path and an archive name. You can also define a
maximum ZIP archive size to make transmission by e-mail easier.
Transferring the diagnostics information to SINUMERIK Integrate
The stored ZIP archive should be transferred to the OEM service or to the hotline,
for example.
7-320
© Siemens AG 2006-2013 All Rights Reserved
SINUMERIK Integrate AMB, AMC, AMM, Function Manual (FH) - 03/2012
03/2012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents