2 USING THE E-MAIL FUNCTION
Setting values for designating the main text
data transmission format
b12
b11
b10
b9
1
0
0
0
2 - 30
(3)
Sample program
The following shows a sample program for sending e-mail by the programmable
controller CPU.
Perform e-mail transmission processing the send command (X20).
The contents of the send data are shown in (4).
Processing program when normal completion
Processing program when abnormal completion
REMARKS
When an error occurs while sending e-mail from the sending mail server to an
external device, an error code is stored in the receiving error log area.
1 The following shows the transmission format of the main text designated in the
control data of the MSEND instruction.
If data is sent as the main text of e-mail, the Ethernet module does not convert
the transmission format.
Designate the main text data in ASCII characters in sequence programs.
b12
to
b8
Completion type
Format set
b8
0
No conversion
When I/O signals of the Ethernet module are X/Y00 to X/Y1F
Designates the transmission format of the main text.
Applicable
station
Send the main text data.
PC/UNIX/
The Ethernet module does not convert the transmission format.
portable
Designate the main text data in ASCII characters in
terminal
sequence programs.
MELSEC-Q/L
Designate main text as the
send data format.
Designates the send destination
number.
Designate the send data length.
Designate the subject length.
Designate Subject.
Designate the main text.
Send the e-mail.
Description of processing
2 - 30