Mitsubishi Electric Melsec Q Series User Manual page 207

Ethernet interface module
Hide thumbs Also See for Melsec Q Series:
Table of Contents

Advertisement

6 DEDICATED INSTRUCTIONS
Device
(S1) + 12
Clock data (set only if an
to
error occurs)
(S1) + 15
Abnormal detection
(S1) + 16
network number (
Abnormal detection station
(S1) + 17
number (
6 - 40
Item
The clock data upon abnormal end is stored in BCD.
This data is stored only when the bit 7 of Abnormal
complete type ((S1) + 0) is 1. The stored value is not
cleared even when the dedicated instruction is normally
completed.
b15
(S1)
12
(S1)
13
(S1)
14
(S1)
15
Year (00
Stores the network number of the station that detected
an abnormality.
This data is stored only when the bit 7 of Abnormal
complete type ((S1) + 0) is 1. The stored value is not
3
)
cleared even when the dedicated instruction is normally
completed.
1 to 239 (Network number)
Stores the station number of the station that detected an
abnormality.
This data is stored only when the bit 7 of Abnormal
complete type ((S1) + 0) is 1. The stored value is not
3
)
cleared even when the dedicated instruction is normally
completed.
1 to 120 (Station number)
1 The "Set by" column indicates the following:
• User: Data is set by the user before executing a dedicated instruction.
• System: The programmable controller CPU stores the execution result of a
dedicated instruction.
2 For a list of error codes, see the User's Manual (Basic).
3 Nothing is stored if the execution source detects an error when receiving an
instruction.
Set data
to
b8
b7
Month (01
to 12
)
Year (00
H
H
H
Hour (00
to 23
)
Date (01
H
H
Minute (00
Second (00
to 59
)
H
H
to 99
), First 2 digits
Day of the week (00
H
H
00
H
MELSEC-Q/L
Setting range
to
b0
to 99
), Last 2 digits
H
to 31
)
H
H
to 59
)
H
H
to 06
)
H
H
(Sun.) to 06
(Sat.)
H
1
Set by (
)
System
System
6 - 40