4 WHEN THE Q/LCPU ACCESSES THE PROGRAMMABLE CONTROLLER
OF ANOTHER STATION USING THE DATA LINK INSTRUCTION
4 - 24
Jn
Local station network number
Start I/O signal of the local station network module/Ethernet
module.
Un
Designate by higher two digits when the I/O signal is
expressed by three digits.
Control data storage head device
(S1)
Designate the head device of the local station that stores
the control data.
Read data storage head device (target station)
(S2)
Designate the head device of the target station that stores
the data to read.
Read data storage head device (local station)
(D1)
Designate the head device of the local station that stores
the data to read.
Read completion device (local station)
Designate the device of the local station to turn on one
scan when the read is complete.
(D2)
(D2) ................... OFF: Incomplete
(D2) + 1 ............. OFF: Normal
Read notify device (target station)
Designate the device of the target station to turn on one
scan when the read is complete.
(D3)
(Can recognize data of target station has been read from
other station.)
(D3) ................... OFF: Incomplete
1: Bit device .................................. X, Y, M, L, F, V, B
2: Word device ............................... T, C, D, W, ST, R, ZR
3: Word device ............................... T, C, D, W, ST, SD, SW, R, ZR
4: Word device bit designation ......
(b) WRITE, SWRITE instructions
[Network number designation]
Write command
JP.WRITE
Write command
JP.SWRITE
[Network module/Ethernet module start I/O signal designation]
Write command
GP.WRITE
Write command
GP.SWRITE
1 The SWRITE instruction can be programmed without argument (D3).
However, in such a case, the operation is identical to the WRITE instruction.
With the SWRITE instruction, different operations are available depending on whether (D3) is omitted
or not.
2 When the target station is a Basic model QCPU or safety CPU, the write notification device set as
argument (D3) for the target station is ignored. (Same operation as with the WRITE instruction)
Setting details
ON: Complete
ON: Abnormal
ON: Complete
.
Word device
Bit number
Jn
(S1)
(S2)
Jn
(S1)
(S2)
Un
(S1)
(S2)
Un
(S1)
(S2)
MELSEC-Q/L
Setting range
1 to 239: Network number
254: Network designated in a
valid module for other station
access.
0 to FE
H
2
Word device
3
Word device
2
Word device
1
Bit device
Word device bit designation
1
Bit device
Word device bit designation
JP: Execution
(D1)
(D2)
JP: Execution
(D1)
(D2)
(D3)
1 2
GP: Execution
(D1)
(D2)
GP: Execution
(D1)
(D2)
(D3)
1 2
4
4
during startup
during startup
during startup
during startup
4 - 24