COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
2-Way Solenoid Valves (Hot Water)
1. Complete the steps
1-5
Fan Panel".
2. Complete the steps
1-3
Side Panel", prior to performing the following steps.
3. Remove the fixing clips of the two hoses of solenoid valve.
Disconnect hoses and power supply cables from the 2-way
solenoid valves (hot water).
2-Way Solenoid Valve (Hot Water)
4. Remove the two screws which are securing the body of 2-way
solenoid valve (hot water) to the support.
2-Way Solenoid Valve (Hot Water)
5. Remove 2-way solenoid valves (hot water).
n
4-24
JennAir Built-in Coffee System
Removing the 2-Way Solenoid Valves
from "Removing the Top Panel and
from "Removing the Back Panel and
2-Way Solenoid Valves (Steam)
1. Complete the steps
1-5
Fan Panel".
2. Complete the steps
1-3
Side Panel", prior to performing the following steps.
3. Remove the fixing clips of the two hoses of solenoid valve.
Disconnect hoses and power supply cables from the 2-way
solenoid valves (steam).
2-Way Solenoid Valve (Steam)
4. Remove the two screws which are securing the body of 2-way
solenoid valve (steam) to the support.
2-Way Solenoid Valve (Steam)
5. Remove 2-way solenoid valves (steam).
from "Removing the Top Panel and
from "Removing the Back Panel and