COMPONENT ACCESS
Removing the Steam Heater & 3-Way Valve
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Remove back panel (page 4-10) to access Steam Heater &
3-Way Valve assembly.
2. To remove the Steam Heater, disconnect the four (4)
hoses shown by the arrows in Figures 1, 2, & 3.
4-14
Jenn-Air Built-in Coffee System
n
Figure 1
Figure 2
3. Unscrew the two (2) screws illustrated in Figure 3.
4. Disconnect the hose going to the 3-Way solenoid valve
shown by the arrow in Figure 4.
5. Disconnect the wiring from the Steam Heater and 3-Way
solenoid valve.
6. Unscrew the two (2) screws securing the 3-Way solenoid
valve to the bracket (see Figure 4).
Figure 4
Figure 3