COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Complete the steps
1-3
Side Panel", prior to performing the following steps.
2. Disconnect the silicone hose from the lower pipe (inlet) of
the pump.
3. Remove the pump and its rubber holder from the chassis of
the appliance.
n
4-16
JennAir Built-in Coffee System
Removing the Water Pump
from "Removing the Back Panel and
4. Disconnect the two hoses (fixed by clips) from the upper
dumper of the pump.
5. Remove the thermal protection and the two power wires
from the pump.