Removing The Grinder Assembly - Jenn-Air W11356996 Service Manual

Built-in coffee system
Table of Contents

Advertisement

COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Complete the steps
1-3
Side Panel", prior to performing the following steps.
2. With a small screwdriver, remove the rubber cap from the
grinder knob. Remove the screw to disconnect grinder
adjustment knob.
3. Lift up the grinder funnel to get access to the grinder
assembly.
n
4-12
JennAir Built-in Coffee System

Removing the Grinder Assembly

from "Removing the Back Panel and
4. Disconnect the motor terminals from the control board
terminals "F1" and "F7."
J8
J7
N
L
L
L
L
F4 F3 F2
5. Lift up the grinder assembly and remove from the coffee
system.
Main
Board
J2
F7
Grinder
Motor
F1

Advertisement

Table of Contents
loading

Table of Contents