Removing The Steam Heater And 3-Way Valve - Jenn-Air W11356996 Service Manual

Built-in coffee system
Table of Contents

Advertisement

Removing the Steam Heater and 3-Way Valve

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Complete the steps
1-3
Side Panel", prior to performing the following steps.
2. With the help of 10 mm wrench remove the two hoses
connected to the inlet and outlet of the steamer.
3. Remove the three hoses by removing the fixing-clips from the
3-way solenoid valve located on the back of the steamer.
from "Removing the Back Panel and
4. Remove the two screws which are securing the steamer
bracket.
5. Remove the cable connections from the steamer. In this way,
the steamer can be easily removed from the appliance.
6. Unscrew the two (2) screws securing the 3-Way solenoid
valve to the bracket.
JennAir Built-in Coffee System
COMPONENT ACCESS
n
4-17

Advertisement

Table of Contents
loading

Table of Contents