Removing The Water Pump - Jenn-Air JBC7624BS Technical Education

Built-in coffee system
Hide thumbs Also See for JBC7624BS:
Table of Contents

Advertisement

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. Remove back panel (page 4-10) to access water pump
assembly (see Figure 1).

Removing the Water Pump

Figure 1
2. Disconnect the three (3) hoses from the water pump (see
Figure 2).
3. Disconnect the power harness from the water pump (see
Figure 2).
4. Using a wrench to keep the white shaft stationary,
unscrew the valve-dumper assembly (see Figure 3).
5. Remove water pump from coffee system.
Jenn-Air Built-in Coffee System
COMPONENT ACCESS
Figure 2
Figure 3
4-13