COMPONENT ACCESS
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or
electrical shock.
1. With a small screwdriver, remove the cap from the
Grinder knob, then remove the screw (see Figure 1).
2. Remove the finger guard. Then remove the coffee bean
storage area from the grinder by removing the screws
illustrated in Figure 2.
4-24
Jenn-Air Built-in Coffee System
n
Removing the Grinder Assembly
Figure 1
Figure 2
3. To remove the grinder assembly, remove the three (3)
screws shown in Figure 3.
4. Then, disconnect the motor terminals from the control
board terminals "F2" and "F7."
J8
J7
N
L
L
L
F4 F3 F2 F1
F2
Figure 4 - Grinder Motor Connections on Main Board
Figure 3
Main
Board
J2
F7
Grinder
Motor
L