SECTION 1 SERVICE INFORMATION
Bit
Error code (hex)
199
00000000 00000080
200
00000000 00000100
201
00000000 00000200
202
00000000 00000400
203
00000000 00000800
204
00000000 00001000
205
00000000 00002000
206
00000000 00004000
207
00000000 00008000
208
00000000 00010000
209
00000000 00020000
210
00000000 00040000
211
00000000 00080000
212
00000000 00100000
213
00000000 00200000
214
00000000 00400000
215
00000000 00800000
216
00000000 01000000
217
00000000 02000000
218
00000000 04000000
219
00000000 08000000
220
00000000 10000000
221
00000000 20000000
222
00000000 40000000
223
00000000 80000000
224
00000001 00000000
225
00000002 00000000
226
00000004 00000000
227
00000008 00000000
228
00000010 00000000
229
00000020 00000000
230
00000040 00000000
231
00000080 00000000
232
00000100 00000000
233
00000200 00000000
234
00000400 00000000
235
00000800 00000000
236
00001000 00000000
237
00002000 00000000
238
00004000 00000000
239
00008000 00000000
240
00010000 00000000
241
00020000 00000000
242
00040000 00000000
243
00080000 00000000
244
00100000 00000000
245
00200000 00000000
246
00400000 00000000
247
00800000 00000000
248
01000000 00000000
249
02000000 00000000
250
04000000 00000000
251
08000000 00000000
252
10000000 00000000
253
20000000 00000000
254
40000000 00000000
255
80000000 00000000
l How to read the returned value and the self-diagnosis serial control command.
Use the command "QVX:ERRS1" to get the information of Self-diagnosis for this model.
The returned value provides the 255bit self-diagnosis information as follows.
(Table below shows no error occurs)
255
• • • •
ERRS1=
N
• • • •
The returned value "N" indicates normal and "E" indicates error status. The first bit 0 starts from right and it ends by 255th bit
at left.
Example: If the self-diagnosis information is inquired under the condition of the projection lens un-mounted, the "E" will ap-
pear on 70th bit as the below.
255
• • • •
ERRS1=
N
• • • •
Self-test indica-
Details
tion
Power CPU communication error
FC0
GEOMETRY communication error
F97
FRC error
FC2
FM-R TEST Fail
F81
FM-G TEST Fail
F82
FM-B TEST Fail
F83
LD1-B Sub CPU error
F65
LD1-S Sub CPU error
F66
LD2-B Sub CPU error
F67
LD2-S Sub CPU error
F68
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
IIC communication error 1 (RTC)
A41
IIC communication error 2 (EEPROM)
A42
IIC communication error 7 (EDID DIGITAL)
A47
IIC communication error 7 (EDID ANALOG)
A48
IIC communication error 9 (ADC1)
A49
IIC communication error 10 (ADC2)
A50
IIC communication error 11 (ACCELERATION SENSOR)
A51
IIC communication error 12 (OPTICAL SENSOR)
A52
IIC communication error 13 (HD BaseT)
A53
IIC communication error 14 (ATM SENSOR)
A54
Sub CPU communication error (R8)
A08
FM communication error
A97
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
bit
200
• • • •
150
• • • •
N
• • • •
N
• • • •
bit
200
• • • •
150
• • • •
N
• • • •
N
• • • •
Probable cause
Communication error on Power CPU
Communication error on Geometry IC
Program transferring error to FRC
Abnormal on FM startup mode
Error on FM memory test
Divice operation error on DR-PCB
Divice operation error on Signal PCB
Communication error on Sub CPU
Communication error on FM
100
• • • •
50
• • • •
N
• • • •
N
• • • •
100
• 70 • •
50
• • • •
N
E
• •
N
• • • •
"E" will appear on 70th bit.
INF-48
1
0
N
N
1
0
N
N
<RZ31K/RS30K>