SECTION 1 SERVICE INFORMATION
2. 3DCMS
• Setting of the 3D Color Management System operation.
- ON : Enable the 3D Color Management system function. (Default setting)
- OFF : Disable the 3D Color Management system function.
3. SELF CHECK
• Self-diagnosing information Displays.
SELF CHECK
MODEL
SERIAL NO.
---------- VERSION --------------
MAIN
SUB
DIGITAL LINK : 1.30.20.5
FPGA
CPLD
FM(R)
FM(G)
FM(B)
LD DRIVER
SELF CHECK
LD SUB
FRC
POWER
---------- DEVICE CHECK ----------
OK : AIR TEMP 123/456
OK : DMD TEMP 123/456
OK : OUT TEMP 123/456
OK : AIR FLOW 123/456/789
OK : LD1B TEMP 123
NG : LD1S TEMP 123
OK : LD2B TEMP 123
OK : LD2S TEMP 123
SELF CHECK
OK : FPGA TEMP 123
OK
: LD1B 1 *
OK
: LD1S 1
0
OK : LD2B 1 1 1 1 1 1
OK : LD2S 1 1 1 1 1 1
NG
: FAN[1] 1111
OK : FAN[2] 1111 1111 1111 1111 1
OK : PHOTO Y 123456.7
OK : ATM 1234/567
OK : ANGLE H -123.4/ V +123.4
OK : SHUTTER 65535 [
[Note]
• Items
to
indicates the status of "NG" or "OK". If the "NG" indicates in red, the projector has an abnormality now. If the
"OK" indicates in red, the projector had an abnormality in the past and operates normally now.
• To clear the error status, press the [MENU] key in the SELF CHECK mode, the confirmation window will appear and select
[OK] to clear.
• This must be done after finishing the repair or maintenance.
: RZ31K
: SW1234567890
: 1.00.00
: 1.00.00
: 01.01/02.02/03.03
: 01.01
: 00.0400.00
: 00.0400.00
: 00.0400.00
: 01.00/01.00/01.00/01.00
DEVICE CHECK : OK
: 01.00/01.00/01.00/01.00
: 1.00.00
: 1.00.00
DEVICE CHECK :
0
1 1 1
1 1 1 *
1110
1111 1111 1111
0]
DEVICE CHECK :
CLEAR ERROR INFOMATION?
OK
① – Model name
1/3
② – Serial no.
------------------- VERSION-----------------------------
③ – Main CPU firmware version
④ – Sub CPU firmware version
⑤ – Digital Link firmware version
⑥ – Digital Link firmware version
⑦ – FPAG firmware version
⑧ – (R/G/B) Formatter firmware version
⑨ – LD driver (LD1B/LD1S/LD2B/LD2S) firmware version
⑩ – LD Sub driver firmware version
2/3
⑪ – FRC firmware version
⑫ – Power firmware version
------------------- DEVICE CHECK-----------------------------
⑬ – Intake air temperature (Celsius/Fahrenheit)
⑭ – DMD temperature (Celsius/Fahrenheit)
⑮ – Exhaust air temperature (Celsius/Fahrenheit)
⑯ – Airflow sensor
tion value)
⑰ – LD1B temperature (Celsius)
⑱ – LD1S temperature (Celsius)
⑲ – LD2B temperature (Celsius)
⑳ – LD2S temperature (Celsius)
NG
3/3
– FPGA temperature (Celsius)
– LD1B check (1: normal / 0: abnormal / *: intentional Off)
– LD1S check (1: normal / 0: abnormal / *: intentional Off)
– LD2B check (1: normal / 0: abnormal / *: intentional Off)
– LD2S check (1: normal / 0: abnormal / *: intentional Off)
– Fan[1] check (1: normal / 0: abnormal)
– Fan[2] check (1: normal / 0: abnormal)
– Luminance sensor check (detected value)
Atmospheric pressure sensor check
value/Temperature detected value)
– Angle sensor check (Horizontal angle / Vertical angle)
– Shutter control check (Opening and shutting times
[Failure times])
NG
㉜ – Device check (OK: Normal, NG: abnormal)
CANCEL
INF-14