LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level. When the Smoke Cut Filter is used, the projector
cannot be used at an altitude of 1 400 m (4 593') or higher above sea level.
*2 Maintenance of the Smoke Cut Filter is not possible. Replace with new one.
Note
SECTION 1 SERVICE INFORMATION
f If the temperature indicator <TEMP> is still lit or blinking after taking the measures, ask your dealer for repair.
Filter indicator <FILTER>
r When the air filter unit/Replacement Filter Unit (Model No.: ET‑EMF330) is attached
Indicator status
f The filter is clogged.
f The runtime of the filter exceeds the
recommended time to replace the
Lighting in red
filter.
f The temperature around or outside
the projector is abnormally high.
f The air filter unit is not attached.
Blinking in red
f The Long Life Filter Unit or Smoke
Cut Filter is not attached.
*1 When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG
LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level.
r When the Long Life Filter Unit (Model No.: ET-EMFU330) is attached
Indicator status
f The filter is clogged.
f The runtime of the filter exceeds the
recommended time to replace the
Lighting in red
filter.
*1
f The temperature around or outside
the projector is abnormally high.
Blinking in red
f [FILTER TYPE]
*1 If the following two conditions are fulfilled, the recommended time to replace the filter is not set.
f The [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to anything other than [HIGH].
f The [PROJECTOR SETUP] menu → [FILTER SETTING] → [FILTER TYPE] is set to [LONG LIFE].
*2 When the [PROJECTOR SETUP] menu → [OPERATION SETTING] → [OPERATING MODE] is set to [LONG LIFE1], [LONG LIFE2], or [LONG
LIFE3], the projector cannot be used at an altitude of 2 700 m (8 858') or higher above sea level.
*3 [FILTER TYPE] can be set in the [PROJECTOR SETUP] menu → [FILTER SETTING] → [FILTER TYPE].
Chapter 6 Maintenance — Light source/temperature/filter indicators
r When the Smoke Cut Filter (Model No.: ET-SFR330) is attached
Indicator status
194 - ENGLISH
f The filter is clogged.
f The runtime of the filter exceeds the
recommended time to replace the
Lighting in red
filter.
f The temperature around or outside
the projector is abnormally high.
Blinking in red
f [FILTER TYPE]
*1 [FILTER TYPE] can be set in the [PROJECTOR SETUP] menu → [FILTER SETTING] → [FILTER TYPE].
Note
f If the filter indicator <FILTER> is still lit or blinking after taking the measures, ask your dealer for repair.
Status
f Perform maintenance or replacement of the filter in the following cases.
g The filter is dirty.
g The recommended time to replace the filter has been exceeded.
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 4 200 m (13 780')
above sea level.
f Attach the air filter unit/Replacement Filter Unit.
Status
f Perform maintenance or replacement of the filter in the following cases.
g The filter is dirty.
g The recommended time to replace the filter has been exceeded.
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 4 200 m (13 780')
above sea level.
is set to [NORMAL]. f Set [FILTER TYPE]
*3
Status
f Replace the Smoke Cut Filter in the following cases.
g The filter is dirty.
g The recommended time to replace the filter has been exceeded.
f Remove any objects if they are blocking the air intake/exhaust port.
f Do not use the projector at an altitude of 1 400 m (4 593') or higher above
sea level.
is set to [NORMAL]. f Set [FILTER TYPE]
*1
Solution
Solution
to [LONG LIFE].
*3
Solution
to [SMOKE CUT].
*1
INF-38
<RZ31K/RS30K>