Single piping left with grown-on facing
Fig. 52: Single piping left with grown-on facing
(11) - Stop
To position a single pipe left with grown-on facing:
1. Position the piping strip at the stop (11) on the left folding plate.
Sewing with flap
Depending on the area of application, the following additional equipment
is required for the simultaneous sewing-in of flaps or other additional parts:
• Production of trousers: Flap clamp right
• Production of jackets: Flap clamp left
60
NOTICE
Property damage may occur!
Damage to the machine caused by the folding plate.
With grown-on facing the right folding plate must not close. Pull the
hose coupling off the right transport clamp.
⑪
Operating Instructions 745-35-10 S/745-35-10 A - 03.0 - 04/2017
Operation